| 제목 | The study about deformation of a Peristaltic Pump using Numerical Simulation |
|---|---|
| 분야 | 디젤엔진 |
| 언어 | English |
| 저자 | 임옥택(울산대학교) |
| Key Words | Peristaltic pump, Deformation, Stress, Fluid flow rate, Ansys. |
| 초록 |
A simulation study was conducted to investigate and optimize a peristaltic pump in fluid flow rate, deformation, and stress under the effects of changing soft tube dimensions. The simulated peristaltic pump including two main components such as a soft tube and a roller was created in a Catia drawing software based on specifications of a real peristaltic pump before imported into a commercial Ansys software to calculate deformation, stress and flow rate of the pump. The simulation results showed that by increasing dimension of the tube from 2mm to 4mm, the deformation and stress of the soft tube is increased accordingly. However, the increase of soft tube dimension showed a benefit for fluid flow rate. The highest flow rate was found at the tube thickness and dimension of 1mm and 4mm, respectively. |
| 원문(PDF) | 다운로드 |