Skip Navigation
Skip to contents

한국자동차공학회

Login

103-103 2005 [Internal Combustion Engine Symposium 2005]

제목 Development of Portable LDA Flow Rate Meter for Fuel Injection Analysis
분야 Engine, Emission Technology
언어 English
저자 Tsuneaki Ishima(Gunma University), Akira Mizuno(Gunma University), Yoshiyuki Kobayashi(Gunma University), Tetsuji Koyama(Tsukasa Sokken), Tomio Obakota(Gunma University)
Key Words Engine Component, Research & Development / Flow rate measurement, Pipe flow, LDA, Fuel injection rate, Gasoline spray
초록 The author's group has developed a flow rate meter based on the laser Doppler anemometer (LDA). The LDA flow rate meter will be expected in the real time fuel injection rate monitoring under a firing condition. In the present study, a compact-size LDA optical system is developed using a diode laser. Moreover, an integrated post signal processing program is proposed combined with Doppler signal acquisition circuit. The new system is applied for high-pressure gasoline injection system.