Skip Navigation
Skip to contents

한국자동차공학회

Login

25권 1호 71-82 2024 [IJAT]

제목 Comparative Study on Brake PM10 Emissions of Vehicle and Brake Dynamometer Under Different Road Conditions
분야 Electric, Fuel Cell, and Hybrid Vehicle
언어 English
저자 SUNG PIL JUNG(Korea Automotive Technology Institute), Chan Hyuk Nam(Korea Automotive Technology Institute), PilGu Lee( Korea Automotive Technology Institute), seoyeon ahn( Korea Automotive Technology Institute), Sung Jin Choi( Korea Automotive Technology Institute)
Key Words Vehicle · Brake dynamometer · Brake particle matter · Dust cover · PM 10 · Test mode
초록 This study proposes a system that can collect and analyze the brake particle matter generated from a vehicle and brake
dynamometer. A dust cover is developed to collect brake particle matter, and the number of particle matter by size is measured
using a portable aerosol spectrometer. Brake PM 10 generated when the vehicle is driving on highways, country and city roads
is collected and analyzed. Based on the vehicle driving data, the test mode for the brake dynamometer is developed using
the relationship between brake energy and brake power. The same brake fi ne dust collection and measurement system as the
vehicle is installed on the brake dynamometer, and brake PM 10 generated according to the test mode for each road condition
is collected and analyzed. As a result, the total number of brake PM 10 collected from the vehicle and brake dynamometer
shows about maximum of 20% error rate for each road condition. The Pearson correlation coeffi cient for the test results is
0.9988, and it means that the vehicle and brake dynamometer test results has a strong positive relationship.
미리보기 다운로드